LIFEGUARD Hydrated Mica Suspension for Lithium-Ion Battery Fire Protection

LIFEGUARD Hydrated Mica Suspension for Lithium-Ion Battery Fire Protection

A water-based mineral extinguishing agent for Lion-Ex portable extinguishers and engineered fire suppression systems.

LIFEGUARD Hydrated Mica Suspension (HMS) is a fire extinguishing agent from United Fire Equipments Pvt. Ltd., developed for applications involving lithium-ion battery fire risks. It is used in the Lion-Ex portable extinguisher range and in LIFEGUARD’s engineered fire suppression systems. The appropriate configuration depends on the batteries in use, how they are housed and the area that needs protection. www.lifeguardindia.in

Request an HMS Datasheet · Book a Product Demonstration · Get a Project Quotation

What is Hydrated Mica Suspension?

Hydrated Mica Suspension is a water-based formulation containing dispersed mineral particles. The LIFEGUARD Material Safety Data Sheet (MSDS) identifies the mineral component as vermiculite. The water component absorbs heat, while the suspended particles provide mineral coverage on surfaces reached by the discharge. www.lifeguardindia.in

Lithium-ion battery incidents can involve thermal runaway, a self-heating reaction that can spread from one cell to others. A battery can also reignite after visible flames have been extinguished. When evaluating HMS for a site, review the battery’s chemistry and energy capacity, whether the affected area is accessible to the discharge, and what the applicable fire test documentation covers. www.usfa.fema.gov

LIFEGUARD HMS product configurations

ConfigurationWhat to reviewLion-Ex portable HMS fire extinguishersFor defined hazards such as battery inspection, device testing and repair workstations, review the proposed model’s datasheet and fire test documentation against the battery configuration at the site.Engineered fixed HMS suppression systemsFor battery cabinets, rooms and containerised battery energy storage systems (BESS), review the enclosure layout, detection requirements, agent distribution and interfaces with the site’s alarm and emergency isolation arrangements.

The LIFEGUARD catalogue reports fire testing in accordance with NTA 8133 for its HMS extinguisher range. Ask for the test report relevant to the proposed model to verify the battery configuration and test conditions. Fixed HMS systems are engineered for the individual project. mail.lifeguardindia.in

Where to evaluate HMS fire protection

FacilityAreas to include in the fire risk assessmentBattery manufacturing and assemblyCell inspection benches, pack assembly lines and quality-control stationsEV service centres and fleet workshopsBattery diagnostics, designated service bays and pack-handling areasElectronics manufacturing and repairDevice testing, battery replacement benches and charging stationsBattery warehouses and logistics facilitiesIncoming inspection, storage, returns handling and designated areas for damaged batteriesResearch and test laboratoriesPrototype development areas and battery test enclosuresBattery energy storage projectsBattery cabinets, rooms, racks and containerised BESS installations

For fixed-system projects, HMS can form part of a fire protection design that includes early detection, alarms, emergency isolation and site response procedures. The system design depends on the enclosure, the battery installation and the project’s operating conditions. updates.lifeguardindia.in

Frequently asked questions

What is the difference between LIFEGUARD HMS and Lion-Ex?

HMS is the Hydrated Mica Suspension extinguishing agent. Lion-Ex is LIFEGUARD’s portable extinguisher range filled with that agent. LIFEGUARD also uses HMS in engineered fixed suppression systems. mail.lifeguardindia.in

Can HMS be specified for an enclosed battery pack?

Suitability depends on the pack construction, access to the affected area and the conditions covered by the applicable test documentation. Share the battery chemistry, energy capacity and enclosure details with the LIFEGUARD technical team for review. www.usfa.fema.gov

What documents should I request for a tender or technical submittal?

Request the HMS Material Safety Data Sheet, the technical datasheet for the proposed model or system, and the applicable fire test or compliance documentation. For a fixed system enquiry, include the project layout, battery details and fire protection specification. www.lifeguardindia.in

Discuss your battery fire protection requirement

Contact United Fire Equipments Pvt. Ltd. (LIFEGUARD), New Delhi for product selection, technical documentation, demonstrations and quotations. Share your site location, battery type, energy capacity in Wh or kWh, cell or pack configuration, and the area to be protected. For a portable extinguisher enquiry, include the required quantity. For a fixed system enquiry, include available drawings and details of existing detection and alarm systems.